logo
خونه > محصولات > 3051 فرستنده روزمونت >
3051SFA Annubar Volume Flow Meter – High-Accuracy Differential Pressure Flow Measurement for Liquids, Gases, and Steam

3051SFA Annubar Volume Flow Meter – High-Accuracy Differential Pressure Flow Measurement for Liquids, Gases, and Steam

3051SFA Annubar flow meter,high-accuracy differential pressure flow meter,flow measurement for liquids gases steam

high-accuracy differential pressure flow meter

flow measurement for liquids gases steam

محل منبع:

سنگاپور

نام تجاری:

rosemount

شماره مدل:

3051SFA

با ما تماس بگیرید
درخواست نقل قول
جزئیات محصول
ثبات:
±0.2% URL/سال
خروجی سیگنال:
سیم 4-20ma 2
حفاظت از ورود:
IP66 ، IP67 ، NEMA 4X
ماده پوسته آلومینیوم:
فولاد ضد زنگ
نوع محصول:
فرستنده
گواهینامه ها:
ATEX، FM، CSA، IECEx، INMETRO، NEPSI، KOSHA، GOST-R
سبک نصب:
راه آهن یا لوله لوله
نمایش:
LCD ، 5 رقمی ، 7 بخش
دمای محیط:
-40 تا 185 درجه فارنهایت (-40 تا 85 درجه سانتیگراد)
نوع اندازه گیری:
فشار
خروجی:
4-20 کارشناسی ارشد ، هارت ، بنیاد Fieldbus
سیگنال خروجی:
4 ~ 20mA پروتکل هارت را تصویب می کند
طول:
-25 تا 25 inH2O / 0.5 inH2O
درجه دقت:
0.05 ≥
دمای فرآیند:
-40 تا 185 درجه فارنهایت (-40 تا 85 درجه سانتیگراد)
برجسته کردن:

3051SFA Annubar flow meter,high-accuracy differential pressure flow meter,flow measurement for liquids gases steam

,

high-accuracy differential pressure flow meter

,

flow measurement for liquids gases steam

شرایط پرداخت و حمل و نقل
مقدار حداقل تعداد سفارش
1
قیمت
قابل مذاکره
جزئیات بسته بندی
کارتن
زمان تحویل
5-7 روز کاری
شرایط پرداخت
L/C، T/T
توضیحات محصول

3051SFA Annubar Volume Flow Meter – High-Accuracy Differential Pressure Flow Measurement for Liquids, Gases, and Steam

The Rosemount 3051SFA Annubar Volume Flow Meter delivers high-accuracy differential pressure flow measurement for liquids, gases, and steam. Featuring Emerson’s patented averaging pitot tube technology, it minimizes permanent pressure loss while providing reliable, repeatable results across a wide range of applications. With integrated pressure and temperature sensors, the 3051SFA enables direct calculation of mass and volume flow, reducing installation complexity and improving process efficiency. Its robust design, advanced diagnostics, and multiple communication protocols make it ideal for critical industrial environments such as power generation, chemical processing, and oil & gas.

3051SFA Annubar Volume Flow Meter – High-Accuracy Differential Pressure Flow Measurement for Liquids, Gases, and Steam 0


Parameter 3051SFA Annubar 3051SF DP Flow Meter 485 Annubar 8705/8732 Electromagnetic 3051S MultiVariable
Measurement Principle Differential Pressure (Averaging Pitot Tube) Differential Pressure + Primary Element (Orifice, Venturi, etc.) Insertion-type Pitot Tube (multiport averaging) Electromagnetic induction Differential Pressure + Pressure + Temperature
Accuracy ±0.75% of flow rate ±0.9% of flow rate ±1% of flow rate ±0.15% of reading ±0.9% of flow rate
Flow Range / Ratio Up to 200:1 turndown Up to 14:1 turndown Wide range, scalable with pipe size 13:1 turndown Flexible depending on configuration
Output Parameters DP, Static Pressure, Temp, Volume Flow, Mass Flow, Energy Flow DP, Volume Flow, Mass Flow DP, Volume Flow Volume Flow only Mass Flow, Volume Flow, Energy Flow
Typical Applications Steam, Gas, Liquid pipelines; energy metering General industrial process control Large pipelines, retrofit installations Water treatment, chemical, food & beverage (conductive liquids) Custody transfer, steam/gas metering

Applications

The Rosemount 3051SFA Annubar Volume Flow Meter is engineered for reliable and accurate flow measurement across a wide range of industrial processes. Typical applications include:

  1. Steam Measurement – High-accuracy monitoring of saturated and superheated steam in power generation, district heating, and process industries.
  2. Gas Flow Monitoring – Measurement of natural gas, compressed air, and other industrial gases for energy management and process optimization.
  3. Liquid Flow Measurement – Accurate volume flow of water, condensate, and process liquids in pipelines and distribution networks.
  4. Energy and Utility Management – Integrated mass and energy flow calculations for cost allocation, efficiency tracking, and system balancing.
  5. Custody Transfer and Compliance – Suitable for applications requiring traceable, repeatable, and auditable flow measurement.
  6. Retrofit and Large-Diameter Pipelines – Insertion-style Annubar design minimizes installation costs and pressure loss, making it ideal for upgrades and large-scale systems.

Frequently Asked Questions (FAQ)

Q1: What is the Rosemount 3051SFA Annubar Volume Flow Meter?
A: It is a high-accuracy differential pressure flow meter that uses Emerson’s patented Annubar averaging pitot tube technology to measure the volume flow of liquids, gases, and steam.

Q2: What makes the 3051SFA different from traditional differential pressure flow meters?
A: Unlike orifice plates or Venturi tubes, the Annubar design minimizes permanent pressure loss, reduces installation costs, and provides multi-variable measurement (pressure, temperature, mass flow, and energy flow).

Q3: What types of media can it measure?
A: The 3051SFA is suitable for steam, natural gas, compressed air, and a wide range of liquids in industrial pipelines.

Q4: What is the accuracy of the 3051SFA?
A: It offers up to ±0.75% of flow rate accuracy with a turndown ratio of up to 200:1, making it highly reliable for critical applications.

Q5: What communication protocols are supported?
A: The device supports HART, WirelessHART, FOUNDATION Fieldbus, and other industry-standard protocols for seamless integration into process control systems.

Q6: Where is the 3051SFA typically used?
A: Common applications include power generation (steam metering), oil & gas (natural gas pipelines), chemical processing, and utility management for energy efficiency.

Q7: Does the 3051SFA provide both volume and mass flow?
A: Yes. With integrated pressure and temperature sensors, it can calculate both volume flow and mass flow, as well as energy flow.

Q8: How does installation compare to other flow meters?
A: The insertion-style Annubar design simplifies installation, especially in large-diameter pipelines, and reduces downtime compared to traditional primary elements.